    SIPOS 5 Flash
    电动执行机构的 使用说明书
    Modbus RTU 接口
    2007年2月版 版权所有! 订购号:E20185-P920-B706-X-5D00
    © SIPOS Aktorik GmbH 2007内容 页码
    1 安全须知······················································································································3
    1.1 和安全有关的术语·····················································································································3
    2 SIPOS 5 Flash电动执行机构的Modbus总线接口······················································3
    2.1 概述··········································································································································3
    2.2 Modbus总线接口······················································································································4
    2.3 Modbus RTU – 基本功能··········································································································4
    2.3.1 报文结构·······················································································································································4
    2.3.2 Modbus串行通讯的消息帧···························································································································5
    2.3.3 三种PDU类型 – 通讯过程·····························································································································5
    2.3.4 数据模型·······················································································································································6
    2.3.5 功能码 – 支持的服务····································································································································6
    3 技术数据及功能···········································································································7
    3.1 带Modbus RTU总线接口的SIPOS 5 Flash电动执行机构··························································7
    3.2 带Modbus 总线接口的SIPOS 5 Flash电动执行机构 – 基本功能···············································8
    3.3 带Modbus总线接口的SIPOS 5 Flash电动执行机构 – 附加的功能··········································10
    3.4 电气连接(铜缆或光纤)········································································································11
    4 设置Modbus RTU的通讯参数···················································································13
    4.1 Modbus RTU的通讯参数········································································································13
    4.2 可选项∕设定工具···················································································································13
    5 使用带Modbus 总线接口的SIPOS 5 Flash电动执行机构········································14
    5.1 通过Modbus总线进行控制······································································································14
    5.2 禁止就地控制单元···················································································································14
    5.3 显示的故障信息(专业型PROFITRON)···············································································14
    6 广播方式及安全功能··································································································15
    6.1 广播信息·································································································································15
    6.2 Modbus的安全功能·················································································································15
    7 Modbus RTU的冗余型·····························································································15
    8 连接状态和故障信号··································································································16
    8.1 连接状态·································································································································16
    8.2 总线通讯故障∕和校验故障····································································································16
    9 参考文献····················································································································34
    附录
    A 输入寄存器······················································································································17-22
    B 保持寄存器······················································································································23-30
    C 离散量输入····························································································································31
    D 线圈·······································································································································32
    E 电报:“读取异常状态”,“报告从站标识”及“读取设备标识” ·····································33
    第2页 E20185-P920-B706-X-5D001 安全须知
    警告标识,表明如果操作不正确,会影响人身或设备的安全。
    1.1 和安全有关的术语
    本手册描述了SIPOS 5 Flash电动执行机构的Modbus总线接口。你还可以在中文使用说明书E20185-P920-B701-X-5D00( 专
    业型PROFITRON)及E20185-P920-B700-X-5D00(经济型ECOTRON)中找到更多的关于SIPOS 5 Flash电动执行机构详细信
    息,包括电气和机械连接,参数设置和调试等。
    出厂前,所有具有Modbus总线通讯能力的执行机构都预先安装了Modbus总线接口,并进行了测试。
    本手册必须同执行机构相应的使用说明书结合在一起来使用。
    当进行同执行机构有关的工作时,必须遵守包含在使用说明书中的安全准则。本手册只包含有Modbus总线接口的有关内容!
    建议由SIPOS AKTORIK服务中心的服务和支持人员进行所有的计划、安装、调试和服务的工作。
    2 SIPOS 5 Flash电动执行机构的 Modbus总线接口
    2.1 概述
    • 关于Modbus RTU的一般知识
    为了在自动化系统之间、自动化系统和所连接的分散的现场设备之间进行信息交换,如今串行现场总线被主要用作通讯系
    统。成千上万的应用已经强烈地证明了通过使用现场总线技术,可以节省多至40%的接线、调试及维护的费用。
    仅仅使用两根电线就可以传送现场设备的所有相关信息,比如输入和输出数据、参数、诊断数据。过去使用的现场总线往
    往是制造商的特定现场总线,并且同其它现场总线不兼容。如今使用的现场总线几乎是完全公开和标准化的。这就意味者用户
    可以以最合理的价格选择最好的产品,而不用依赖于每个独立的制造商。
    Modbus RTU是一种国际的、开放的现场总线标准。作为一种很容易实现的现场总线协议,在全世界范围内,Modbus得到
    了成功的应用。应用领域包括生产过程中的自动化、过程控制和楼宇自控。
    • 基本特征
    Modbus RTU决定了一个由它把分散的数字自动化设备连接在一起的、串行现场总线系统的技术和功能特点。它被设计成
    在现场级以极高的速度传递数据。这里的中央控制设备,比如PLC或PC机,通过有关高速的串行接口同外围的现场站进行开关
    量及∕或模拟量的输入输出数据通讯。
    基本的是非循环通讯服务。
    Modbus区别主站设备和从站设备。
    主站设备 控制总线上的数据交换。主站被允许毋需一个外部请求就可以发送信息。
    从站设备 诸如SIPOS 5 Flash电动执行机构等的外围设备。典型的从站设备是输入输出设备,阀门,执行机构和测量变送
    器。它们不具备访问总线的能力,也就是说,它们仅仅可以确认已经接受到的信息,或者,在主站的要求下发送信息到主站。
    从站通常也被称作被动站。
    一般适用下列规则:
    o 在一条总线上,只允许有1个主站可以在工作状态(单主站总线系统)。
    o 最多可以有247个从站被连接到一条总线上。
    o 总是由主站启动通讯,从站只能是响应主站的请求。
    o 保护特点:“和校验”及奇偶校验位。
    E20185-P920-B706-X-5D00 第3页主站同现场设备(从站)的通讯有两种方式:
    o 单独通讯方式 – 直接向一个特定的现场
    设备发出请求。
    (从站地址不能为“0”):
    “正常”操作: 主站
    主站向某个现场设备发出请求,该设备随 请求 响应
    后作出响应。
    从站
    从站
    从站
    o 广播方式 – 针对所有现场设备的总的请
    求。
    (从站地址为“0”):
    主站发送一个请求(报文)给所有的总线 主站
    站。例如,发送一个“紧急”命令,而不 请求
    需要任何从站的响应。
    更进一步的说明,请参考第6.1节。
    从站
    从站
    从站
    2.2 Modbus总线接口
    • 1通道或2通道(冗余型)。
    • 适用于所有的多回转、直行程或角行程电动执行机构,以及两种控制单元,经济型(ECOTRON)和专业型(PROFITRON)。
    0/200
    会员专享 开通会员
    升级会员获取海量资源免费下载
    会员免费下载
    5D币 购买
    上传资源赚收益
    格式:pdf
    浏览:222
    收藏:0
    浏览:222  |   收藏:0
    上传时间:2016-07-01
    大小:1.6MB
    举报
    作者相关作品
    加载失败
    浏览:222  |   收藏:0
    浏览:222
    收藏:0
    加载失败
    浏览:146  |   收藏:0
    浏览:146
    收藏:0
    排名
    昵称
    瓦特值
    7
    15
    复制下方链接,分享给好友同事
    或微信扫描下方二维码一键分享给好友
    复制下方链接,分享给好友同事
    或微信扫描下方二维码一键分享给好友
    Blogroll: Leadsoft
    利驰数字科技(苏州)有限公司版权所有    增值电信业务经营许可证
    Contact us
    官方公众号
    400-6699-000 工作日 9:00-17:00
    利驰数字科技(苏州)有限公司
    VIP
    问答
    客服
    反馈
    赚钱
    加载失败
    资源详情
    评论建议
    电动执行机构的MODBUS RTU接口使用说明书
    作品总数  2
    V1
    作品详情
    浏览:222
    大小:1.6MB
    下载:0
    收藏:0
    时间:2016-07-01
    格式:pdf
    作品介绍
    德国西博思 电动执行机构的MODBUS RTU接口使用说明书

    声明:您必须遵守我们的协议,如果您下载了该资源行为将被视为对《电天下账号管理规范》全部内容的认可,本网站资源来自原创,仅供用于学习和交流,请勿用于商业用途。如有侵权、不妥之处,请举报本资源,我们将及时审核处理!
    举报
    评论区 (0)
    0/200
    缩略图
    名称
    数据类型
    暂无数据
    隐藏
    VIP
    问答
    赚钱