UPS 安装手册
40–60–80–100–125–160–200–250–300kVA
1概述与安装
UPS 概述与安装
目录
1. 简介 ......................................................................................................3
2. 概述 .....................................................................................................3
2.1 结构.................................................................................................................. 3
2.2 系统描述........................................................................................................... 4
2.2.1 整流器 ....................................................................................................... 4
2.2.2 逆变器 ....................................................................................................... 4
2.2.3 电池与充电器............................................................................................. 4
2.2.4 静态旁路.................................................................................................... 4
2.2.6 面板........................................................................................................... 4
2.3 工作状态........................................................................................................... 5
2.3.1 正常工作状态............................................................................................. 5
2.3.2 因逆变器故障导致的旁路带载.................................................................... 5
2.3.3 整流器故障或市电故障.............................................................................. 5
2.3.4 维修旁路.................................................................................................... 6
3. 安装 .....................................................................................................6
3.1 到货.................................................................................................................. 6
3.2 搬运.................................................................................................................. 6
3.3 定位和安装 ....................................................................................................... 7
3.3.1 底面、静负荷和重量.................................................................................. 7
3.3.2 尺寸和距离................................................................................................ 8
3.4 电气连接........................................................................................................... 9
3.4.1 A.接线端(40-80KVA)........................................................................ 10
3.4.2 B.接线端(100-160KVA)..................................................................... 10
3.4.3 C.接线端(200-300KVA)..................................................................... 10
3.5 电池连接和定位.............................................................................................. 11
2概述与安装
1. 简介
本手册旨在简要描述UPS的一般构成,并指导安装使用者,在选定的房间内正确安装
系统。
安装使用者应认真仔细阅读本手册,根据指导正确完成单机安装,尤其应遵守国家相
关的安全性强制标准。
对于未执行上述要求所造成的设备损坏或人身伤害,制造商不承担任何责任。
2. 概述
2.1 结构
本手册所指UPS均为在线式、双转换;无论市电可用或不可用(取决于电池后备时
间),均为逆变器带载。
警告
即使当市电故障时,UPS输出端仍然带电。根据EN 50091-1要求,安装者必须甄别由
UPS供电的电线或插头,并告知使用者。
这种结构保证了为用户提供最好的服务,因为它提供的是清洁、连续可调的电源,并
保证电压频率不受电源状况的影响而保持稳定。正是由于双转换,使得负载不再因市电
剧烈波动而造成微小中断,并可预防关键负载的损坏(计算机-使用仪器-科学设备等)。
图 1 – 框图
3概述与安装
2.2 系统描述
2.2.1 整流器
整流器将市电三相电压转换为连续的直流电压。
UPS采用了全数字控制的IGBT三相整流桥,可以极大地降低谐波失真。(EA99L 系列
可控硅相控整流)
采用这种结构可以将市电谐波失真降低到5%以下(EA99L系列:30%以下)。
这样就可以保证,无论负载如何,整流器将不会造成市电电压畸变,并且可以避免因
谐波电流过大而造成的电缆过热。
整流器设计功率为逆变器带满载功率同时为电池组提供最大充电电流。
2.2.2 逆变器
将来自整流器或电池的连续电压,转换成具有稳定的幅度和频率的交变电压。
逆变器采用IGBT技术,调制频率约为10 KHz。
控制电路全数字化,并使用16位微处理器。因其优越的处理能力,产生的输出正弦波
相当好,即使在负载出现很高的尖峰电流时,也仅产生很小的失真。
2.2.3 电池与充电器
电池组安装在外置电池柜中。
电池充电器控制功能完全集成于整流控制板上;根据DIN41773标准,每次部分放电或
完全放电后,电池需进行充电,充满后继续浮充以补偿电池自放电损耗。
2.2.4 静态旁路
用于将负载由逆变器供电转换为市电供电,或相反。供电切换不产生间断,使用可控
硅作为转换器件。
警告
旁路操作步骤必须依照UPS上所示程序和“开机、关机、维修旁路”章节中的要求进
行。因错误操作导致的损坏,制造商不承担责任。
2.2.6 面板
UPS面板由两行字符显示屏和5个功能键组成,可完成UPS所有状态的监测。
模拟图用于帮助理解UPS的工作状态。
更多信息请参见“操作手册-面板”一章。
4概述与安装
2.3 工作状态
以下各图描述了UPS可能的几种工作状态。
2.3.1 正常工作状态
逆变器由整流器供电,负载通过静态开关,直接由逆变器输出供电。
图 2 – 正常工作状态
2.3.2 因逆变器故障导致的旁路带载
负载转为旁路静态开关带载,转换过程无中断。
图 3 – 旁路带载
2.3.3 整流器故障或市电故障
逆变器由电池供电并持续到预定的后备时间,负载经静态开关由逆变器输出供电。
5概述与安装
图 4 – 整流器故障或市电故障
2.3.4 维修旁路
市电经维修旁路直接向负载电供电,工作人员可以安全地在UPS内部对其进行维修或
检修操作。
图 5 - 维修旁路
3. 安装
3.1 到货
UPS到货后,请即时打开包装进行仔细检查,以确保运输途中未受损坏。
重要提示
若发生运输途中导致的有关物件损坏,到货后应及时通知运输商。
如果不是立即安装,请根据包装上的指示将UPS竖直存放,连同其包装箱储存在干
40–60–80–100–125–160–200–250–300kVA
1概述与安装
UPS 概述与安装
目录
1. 简介 ......................................................................................................3
2. 概述 .....................................................................................................3
2.1 结构.................................................................................................................. 3
2.2 系统描述........................................................................................................... 4
2.2.1 整流器 ....................................................................................................... 4
2.2.2 逆变器 ....................................................................................................... 4
2.2.3 电池与充电器............................................................................................. 4
2.2.4 静态旁路.................................................................................................... 4
2.2.6 面板........................................................................................................... 4
2.3 工作状态........................................................................................................... 5
2.3.1 正常工作状态............................................................................................. 5
2.3.2 因逆变器故障导致的旁路带载.................................................................... 5
2.3.3 整流器故障或市电故障.............................................................................. 5
2.3.4 维修旁路.................................................................................................... 6
3. 安装 .....................................................................................................6
3.1 到货.................................................................................................................. 6
3.2 搬运.................................................................................................................. 6
3.3 定位和安装 ....................................................................................................... 7
3.3.1 底面、静负荷和重量.................................................................................. 7
3.3.2 尺寸和距离................................................................................................ 8
3.4 电气连接........................................................................................................... 9
3.4.1 A.接线端(40-80KVA)........................................................................ 10
3.4.2 B.接线端(100-160KVA)..................................................................... 10
3.4.3 C.接线端(200-300KVA)..................................................................... 10
3.5 电池连接和定位.............................................................................................. 11
2概述与安装
1. 简介
本手册旨在简要描述UPS的一般构成,并指导安装使用者,在选定的房间内正确安装
系统。
安装使用者应认真仔细阅读本手册,根据指导正确完成单机安装,尤其应遵守国家相
关的安全性强制标准。
对于未执行上述要求所造成的设备损坏或人身伤害,制造商不承担任何责任。
2. 概述
2.1 结构
本手册所指UPS均为在线式、双转换;无论市电可用或不可用(取决于电池后备时
间),均为逆变器带载。
警告
即使当市电故障时,UPS输出端仍然带电。根据EN 50091-1要求,安装者必须甄别由
UPS供电的电线或插头,并告知使用者。
这种结构保证了为用户提供最好的服务,因为它提供的是清洁、连续可调的电源,并
保证电压频率不受电源状况的影响而保持稳定。正是由于双转换,使得负载不再因市电
剧烈波动而造成微小中断,并可预防关键负载的损坏(计算机-使用仪器-科学设备等)。
图 1 – 框图
3概述与安装
2.2 系统描述
2.2.1 整流器
整流器将市电三相电压转换为连续的直流电压。
UPS采用了全数字控制的IGBT三相整流桥,可以极大地降低谐波失真。(EA99L 系列
可控硅相控整流)
采用这种结构可以将市电谐波失真降低到5%以下(EA99L系列:30%以下)。
这样就可以保证,无论负载如何,整流器将不会造成市电电压畸变,并且可以避免因
谐波电流过大而造成的电缆过热。
整流器设计功率为逆变器带满载功率同时为电池组提供最大充电电流。
2.2.2 逆变器
将来自整流器或电池的连续电压,转换成具有稳定的幅度和频率的交变电压。
逆变器采用IGBT技术,调制频率约为10 KHz。
控制电路全数字化,并使用16位微处理器。因其优越的处理能力,产生的输出正弦波
相当好,即使在负载出现很高的尖峰电流时,也仅产生很小的失真。
2.2.3 电池与充电器
电池组安装在外置电池柜中。
电池充电器控制功能完全集成于整流控制板上;根据DIN41773标准,每次部分放电或
完全放电后,电池需进行充电,充满后继续浮充以补偿电池自放电损耗。
2.2.4 静态旁路
用于将负载由逆变器供电转换为市电供电,或相反。供电切换不产生间断,使用可控
硅作为转换器件。
警告
旁路操作步骤必须依照UPS上所示程序和“开机、关机、维修旁路”章节中的要求进
行。因错误操作导致的损坏,制造商不承担责任。
2.2.6 面板
UPS面板由两行字符显示屏和5个功能键组成,可完成UPS所有状态的监测。
模拟图用于帮助理解UPS的工作状态。
更多信息请参见“操作手册-面板”一章。
4概述与安装
2.3 工作状态
以下各图描述了UPS可能的几种工作状态。
2.3.1 正常工作状态
逆变器由整流器供电,负载通过静态开关,直接由逆变器输出供电。
图 2 – 正常工作状态
2.3.2 因逆变器故障导致的旁路带载
负载转为旁路静态开关带载,转换过程无中断。
图 3 – 旁路带载
2.3.3 整流器故障或市电故障
逆变器由电池供电并持续到预定的后备时间,负载经静态开关由逆变器输出供电。
5概述与安装
图 4 – 整流器故障或市电故障
2.3.4 维修旁路
市电经维修旁路直接向负载电供电,工作人员可以安全地在UPS内部对其进行维修或
检修操作。
图 5 - 维修旁路
3. 安装
3.1 到货
UPS到货后,请即时打开包装进行仔细检查,以确保运输途中未受损坏。
重要提示
若发生运输途中导致的有关物件损坏,到货后应及时通知运输商。
如果不是立即安装,请根据包装上的指示将UPS竖直存放,连同其包装箱储存在干
AIGC
尊敬的用户您好!EA99系列UPS(不间断电源)安装手册是一份详细的指南,旨在帮助您正确、安全地安装及配置EA99系列不间断电源产品。该手册包含了以下内容:
1. 产品介绍:对EA99系列UPS的型号、特性、主要功能以及适用场景进行详细介绍,以便您了解其在电力系统中的作用。
2. 安装前准备:涵盖了所需工具清单、环境要求、电源接入方式等重要信息,确保在开始安装之前做好充分准备。
3. 设备组装:指导您如何拆箱、检查组件完整性,并按照步骤详细说明UPS主机、电池柜、市电输入线缆、输出配电盘等关键部件的安装方法。
4. 线路连接:说明市电输入、电池输入、旁路输入、负载出线以及保护接地线的具体连接方式和注意事项。
5. 参数设置与操作说明:包括如何通过控制面板或监控软件设置工作模式、电池测试、告警阈值等相关参数,以及日常运行与维护的操作流程。
6. 故障排除与应急处理:为常见的使用过程中遇到的问题提供解决方案和紧急状态下的应对措施。
7. 安全规定与警示:强调在安装、使用过程中应注意的安全事项,以保障人员及设备安全。
总之,EA99系列UPS安装手册是您完成专业、高效UPS安装工作的必备参考文档,请在正式操作前仔细阅读并严格按照手册指引进行操作。如有任何疑问或需要技术支持,请随时联系我们的客户服务团队。