Automation terminals of the Inline product range

声明:您必须遵守我们的协议,如果您下载了该资源行为将被视为对《电天下账号管理规范》全部内容的认可,本网站资源来自原创,仅供用于学习和交流,请勿用于商业用途。如有侵权、不妥之处,请举报本资源,我们将及时审核处理!

Automation terminals of the Inline product range

Automation terminals of the Inline product range
文本预览
AUTOMATION
User Manual
IL SYS INST UM E
Order No.: 2698737
Automation terminals
of the Inline product rangeAUTOMATION
User Manual
Automation terminals of the Inline product range
07/2008
Designation: IL SYS INST UM E
Revision: 02
Order No.: 2698737
This user manual is valid for:
All automation terminals in the Inline product range without
bus couplers and bus-specific special features
6452_en_02 PHOENIX CONTACTIL SYS INST UM E
Please observe the following notes
In order to ensure the safe use of the product described, you have to read and understand
this manual. The following notes provide information on how to use this manual.
User group of this manual
The use of products described in this manual is oriented exclusively to qualified electricians
or persons instructed by them, who are familiar with applicable standards and other
regulations regarding electrical engineering and, in particular, the relevant safety concepts.
Phoenix Contact accepts no liability for erroneous handling or damage to products from
Phoenix Contact or third-party products resulting from disregard of information contained in
this manual.
Explanation of symbols used and signal words
This is the safety alert symbol. It is used to alert you to potential personal injury
hazards. Obey all safety messages that follow this symbol to avoid possible
injury or death.
DANGER
This indicates a hazardous situation which, if not avoided, will result in death or serious
injury.
WARNING
This indicates a hazardous situation which, if not avoided, could result in death or serious
injury.
CAUTION
This indicates a hazardous situation which, if not avoided, could result in minor or
moderate injury.
The following types of messages provide information about possible property damage and
general information concerning proper operation and ease-of-use.
NOTE
This symbol and the accompanying text alerts the reader to a situation which may cause
damage or malfunction to the device, either hardware or software, or surrounding
property.
This symbol and the accompanying text provides additional information to the reader. It is
also used as a reference to other sources of information (manuals, data sheets, literature)
on the subject matter, product, etc.
PHOENIX CONTACT 6452_en_02IL SYS INST UM E
General terms and conditions of use for technical documentation
Phoenix Contact reserves the right to alter, correct, and/or improve the technical
documentation and the products described in the technical documentation at its own
discretion and without giving prior notice, insofar as this is reasonable for the user. The
same applies to any technical changes that serve the purpose of technical progress.
The receipt of technical documentation (in particular data sheets, installation instructions,
manuals, etc.) does not constitute any further duty on the part of PhoenixContact to furnish
information on alterations to products and/or technical documentation. Any other
agreement shall only apply if expressly confirmed in writing by PhoenixContact. Please
note that the supplied documentation is product-specific documentation only and that you
are responsible for checking the suitability and intended use of the products in your specific
application, in particular with regard to observing the applicable standards and regulations.
Although Phoenix Contact makes every effort to ensure that the information content is
accurate, up-to-date, and state-of-the-art, technical inaccuracies and/or printing errors in
the information cannot be ruled out. PhoenixContact does not offer any guarantees as to
the reliability, accuracy or completeness of the information. All information made available
in the technical data is supplied without any accompanying guarantee, whether expressly
mentioned, implied or tacitly assumed. This information does not include any guarantees
regarding quality, does not describe any fair marketable quality, and does not make any
claims as to quality guarantees or guarantees regarding the suitability for a special purpose.
PhoenixContact accepts no liability or responsibility for errors or omissions in the content
of the technical documentation (in particular data sheets, installation instructions,
manuals,etc.).
The aforementioned limitations of liability and exemptions from liability do not apply, in so
far as liability must be assumed, e.g.,according to product liability law, in cases of
premeditation, gross negligence, on account of loss of life, physical injury or damage to
health or on account of the violation of important contractual obligations. Claims for
damages for the violation of important contractual obligations are, however, limited to
contract-typical, predictable damages, provided there is no premeditation or gross
negligence, or that liability is assumed on account of loss of life, physical injury or damage
to health. This ruling does not imply a change in the burden of proof to the detriment of the
user.
6452_en_02 PHOENIX CONTACTIL SYS INST UM E
Statement of legal authority
This manual, including all illustrations contained herein, is copyright protected. Use of this
manual by any third party is forbidden. Reproduction, translation, and public disclosure, as
well as electronic and photographic archiving or alteration requires the express written
consent ofPhoenixContact. Violators are liable for damages.
Phoenix Contact reserves all rights in the case of patent award or listing of a registered
design. Third-party products are always named without reference to patent rights. The
existence of such rights shall not be excluded.
How to contact us
Internet Up-to-date information on Phoenix Contact products and our Terms and Conditions can be
found on the Internet at:
www.phoenixcontact.com.
Make sure you always use the latest documentation.
It can be downloaded at:
www.download.phoenixcontact.com.
A conversion table is available on the Internet at:
www.download.phoenixcontact.com/general/7000_en_00.pdf.
Subsidiaries If there are any problems that cannot be solved using the documentation, please contact
AIGC
您好,很高兴为您解答关于"Inline产品系列的自动化终端"的问题。 Inline产品系列的自动化终端是一种专为电气系统设计的高级解决方案。这些终端通常集成在生产线或设备中,目的是实现自动化控制和管理。它们可能包括连接器、断路器、继电器、传感器或者控制器等元件,用于数据传输、故障检测、安全保护和远程操作等功能。这些终端简化了系统的安装和维护过程,提高了效率,并且有助于优化生产流程中的智能化操作。如果您有关于具体型号、功能或如何选择使用的问题,请随时告诉我,我会尽力提供详细的信息和支持。
0/200
会员专享
升级会员获取海量资源免费下载
会员免费下载
5D币 购买
上传资源赚收益
格式:pdf
浏览:262
收藏:0
浏览:262  |   收藏:0
上传时间:2010-09-25
大小:6.8M
举报
作者相关作品
浏览:37.5w  |   收藏:2
浏览:37.5w
收藏:2
浏览:18.6w  |   收藏:4
浏览:18.6w
收藏:4
浏览:17.9w  |   收藏:0
浏览:17.9w
收藏:0
浏览:15.0w  |   收藏:1
浏览:15.0w
收藏:1
排名
昵称
瓦特值
复制下方链接,分享给好友同事
或微信扫描下方二维码一键分享给好友
复制下方链接,分享给好友同事
或微信扫描下方二维码一键分享给好友
Blogroll: Leadsoft
利驰数字科技(苏州)有限公司版权所有    增值电信业务经营许可证
Contact us
官方公众号
400-6699-000 工作日 9:00-17:00
利驰数字科技(苏州)有限公司
西安利驰软件有限公司
VIP
问答
客服
反馈
赚钱
资源详情
评论建议
Automation terminals of the Inline product range
作品总数  1.7w
V6
作品详情
浏览:262
大小:6.8M
下载:1
收藏:0
时间:2010-09-25
格式:pdf
作品介绍
Automation terminals of the Inline product range
AIGC
您好,很高兴为您解答关于"Inline产品系列的自动化终端"的问题。 Inline产品系列的自动化终端是一种专为电气系统设计的高级解决方案。这些终端通常集成在生产线或设备中,目的是实现自动化控制和管理。它们可能包括连接器、断路器、继电器、传感器或者控制器等元件,用于数据传输、故障检测、安全保护和远程操作等功能。这些终端简化了系统的安装和维护过程,提高了效率,并且有助于优化生产流程中的智能化操作。如果您有关于具体型号、功能或如何选择使用的问题,请随时告诉我,我会尽力提供详细的信息和支持。

声明:您必须遵守我们的协议,如果您下载了该资源行为将被视为对《电天下账号管理规范》全部内容的认可,本网站资源来自原创,仅供用于学习和交流,请勿用于商业用途。如有侵权、不妥之处,请举报本资源,我们将及时审核处理!
举报
评论区 (0)
0/200
暂无数据
VIP
问答
反馈
赚钱