RD-2X系列产品
声明:您必须遵守我们的协议,如果您下载了该资源行为将被视为对《电天下账号管理规范》全部内容的认可,本网站资源来自原创,仅供用于学习和交流,请勿用于商业用途。如有侵权、不妥之处,请举报本资源,我们将及时审核处理!
RD-2X系列电能表产品(英文)
文本预览
Radian Research, Inc.
RD-20 Dytronic Portable Single-Phase Standard
INTUITIVE USER INTERFACE
The RD-20’s LCD and fi ve-button keypad provides a direct interface to the end
user while the RD-20’s RS-232 port, utilized with the applicable software, allows
for remote PC control and confi guration of the RD-20. Utilizing the fi ve-button
keypad and observing the LCD, the user is able to scroll through the various mea-
surement functions of the RD-20 and toggle between the different menu screens.
The amount of measurement information and the number of menu screens viewable
is determined by the model number of the RD-20.
MENU SCREENS
The key menu screens are the Measurement Screens, Run Test Screen, Harmonics
Screen, and Setup Screen.
The Measurement Screens will display the measurement functions the RD-20 sup-
ports. There are different screens for Instantaneous Measurements, Accumulating
Measurements, and Minimum & Maximum Measurements. Using the keypad, it
is very simple to toggle between the various measurement screens and to scroll
through the various measurement functions.
Typical Accuracy = +/- 0.01%
Worst Case = +/- 0.04% The Main Menu Screen allows users to gain access to the specifi c functionality of
their RD-20. From the Main Menu, the user may select to run a meter or standard
test, perform harmonics analysis, set-up/confi gure their RD-20, perform a self test,
OVERVIEW
and review information pertinent to their RD-20.
PRODUCT HIGHLIGHTS: The Radian RD-20 Single-phase Electricity
Reference Standard is one of the most versatile reference instruments ever. The
RD-20 has a typical accuracy of 0.01% for all measurement functions across
its entire operating range, with a maximum worst case accuracy of 0.04%. This
worst case accuracy specifi cation includes the variables of stability, power factor,
traceability uncertainty and test system errors. The Run Test Screen allows the user to select the type of test they would like to
run and then to enter the different variables for that specifi c test.
The RD-20 utilizes Radian’s new Dytronic measurement technology consisting
of a Radian designed Integrating Analog to Digital Signal Converter. Unlike
off-the-shelf A/D Converters used in other instruments, Radian’s A/D Converter
is specifi cally designed and optimized for power and energy measurement. This
unique design makes the RD-20 absolutely unsurpassed in its ability to accurately
measure “real world” waveforms. The RD-20’s A/D Converter is combined with
Radian’s renowned electronically compensated voltage and current input trans-
formers and a hermetically sealed reference set to provide the highest degree of
accuracy, stability and versatility offered in a portable single-phase standard. In the Harmonics Screen the user may select to view voltage or amperage harmonics,
scroll through the harmonic order to observe the phase and magnitude of a specifi c
MEASUREMENTS: The RD-20 is a four quadrant single-phase, simultane- harmonic, and view the total harmonic distortion.
ous measuring instrument that registers both forward and reverse energy fl ow
and provides voltage, current, power and energy (Active, Reactive, Apparent)
information. The Harmonic Analysis option makes available the analysis of
customer load though the 50th harmonic order while the Built-in Comparator
option provides for the automatic calculation of test results for the meters and
standards being tested.
METER AND STANDARD TESTING: The compact light weight design The Setup Screen allows the user to custom confi gure their RD-20. The options
of the RD-20 makes it an ideal reference standard for fi eld testing applications. available are changing the operation of the BNC ports, enabling or disabling the
The RD-20 may be used with a controlled current source to accurately test rev- backlit display, selecting RMS or AVG measurement response, disabling or enabling
enue meters. In fi eld applications the RD-20 can perform a single-phase meter the RD-20’s audible beeps, auto-scrolling the screens, and returning the RD-20 to
accuracy test using existing service load. Pickups to sense meter disk rotation or its original factory default settings.
calibration pulses of infrared, visible light, or KYZ signal plug directly into the
RD-20. The RD-20 may be utilized to test reference standards of lesser accuracy The above features and functions may also be utilized via a PC running Radian
and is also an ideal standard to be intergraded within a meter test bench where Software packages. RR-Confi gure/Analyze allows for the custom confi guration
lesser accuracy is acceptable.
of the RD-20 along with data analysis and RR-Kit software is a set of commands,
routines, and instructions for custom application development.Technical Specifi cations
OPERATING RANGE RD-20 Menu for Measurements & Functionality: The last three digits determine the model.
Current (Autoranging) The fi rst of the last three digits determines the measurement functions; the second of the
.02 to 67 amps per input (three input option) last three digits determines if the unit has a comparator, harmonics analysis, and/or analog
.02 to 75 amps per input (three input extended range option) sense capability; the third of the last three digits determines the current input confi guration.
.02 to 120 amps per input (one input option)
Input voltage: 30 to 600 volts (Autoranging) Specifying the fi rst of the last three digits: RD-20-Xxx
Auxiliary power input: 60 to 600 volts (Autoranging)
Frequency: 45 to 65 Hz MODEL MEASUREMENT FUNCTIONS
Phase Angle: 0 to 360° or -180 to 180°
Power Factor: -1 to 1 RD-20-1xx Whrs, Volts, Amps, VARhrs
Temperature: –20° to +70°C (-4° to +158°F)
Humidity: 0% to 95% non-condensing RD-20-2xx Whrs, Volts, Amps, VARhrs, VAhrs, Qhrs, Watts, VARs,
VA, Phase Angle, Power Factor, Frequency
Shock and vibration: Any that is not destructive
RD-20-3xx Whrs, VARhrs, VAhrs, Qhrs, Volts, Amps, Watts, VARs, VA,
PHYSICAL DESCRIPTION
Vhr, Ahr, V2hr, A2hr, Phase Angle, Power Factor, Frequency
Weight: 2.5 kg (5.5 lbs); 3.6 kg (8lbs) shipping weight
Min & Max measurements: All indicating functions
Size 190.5 mm (7.5") H x 139.7 mm (5.5") D excluding strap
Backlit LCD, 4 line by 16 character
RD-20-4xx Whrs, Volts, Amps, VARhrs, Qhrs, Vahrs, Watts, VARs, VA,
Current inputs: 6mm jacks
Vhr, Ahr, V2hr, A2hr, Phase Angle, PF, Frequency
Potential and Aux power inputs: 4mm Banana type jacks
Min & Max: All indicating functions
BNC connector (port 1) used for input/gating
AVG response: VAhrs, VA, Volts, Vhrs, Amps, Ahrs
BNC connector (port 2) used for pulse outputs
BNC connector (port 3) used for three phase SYNC or analog sense
Specifying the second of the last three digits: RD-20-xXx
5 membrane button keypad: UP/DOWN/ESC-RESET/ENTER/MODE
8 pin RJ-45 jack for RS-232 communication
-x0x No comparator, No harmonic analysis
Pickup input for direct interface to RR-DS, RR-1H, or RR-KYZ
-x1x Built-in comparator
Clamp-on CT input for optional clamp-on current transformer
-x2x Harmonic analysis (RR-Analyze Software included)
-x3x Built-in comparator AND harmonic analysis
TEST AND CALIBRATION
No physical adjustments, all calibration performed with software
RD-20 Dytronic Portable Single-Phase Standard
INTUITIVE USER INTERFACE
The RD-20’s LCD and fi ve-button keypad provides a direct interface to the end
user while the RD-20’s RS-232 port, utilized with the applicable software, allows
for remote PC control and confi guration of the RD-20. Utilizing the fi ve-button
keypad and observing the LCD, the user is able to scroll through the various mea-
surement functions of the RD-20 and toggle between the different menu screens.
The amount of measurement information and the number of menu screens viewable
is determined by the model number of the RD-20.
MENU SCREENS
The key menu screens are the Measurement Screens, Run Test Screen, Harmonics
Screen, and Setup Screen.
The Measurement Screens will display the measurement functions the RD-20 sup-
ports. There are different screens for Instantaneous Measurements, Accumulating
Measurements, and Minimum & Maximum Measurements. Using the keypad, it
is very simple to toggle between the various measurement screens and to scroll
through the various measurement functions.
Typical Accuracy = +/- 0.01%
Worst Case = +/- 0.04% The Main Menu Screen allows users to gain access to the specifi c functionality of
their RD-20. From the Main Menu, the user may select to run a meter or standard
test, perform harmonics analysis, set-up/confi gure their RD-20, perform a self test,
OVERVIEW
and review information pertinent to their RD-20.
PRODUCT HIGHLIGHTS: The Radian RD-20 Single-phase Electricity
Reference Standard is one of the most versatile reference instruments ever. The
RD-20 has a typical accuracy of 0.01% for all measurement functions across
its entire operating range, with a maximum worst case accuracy of 0.04%. This
worst case accuracy specifi cation includes the variables of stability, power factor,
traceability uncertainty and test system errors. The Run Test Screen allows the user to select the type of test they would like to
run and then to enter the different variables for that specifi c test.
The RD-20 utilizes Radian’s new Dytronic measurement technology consisting
of a Radian designed Integrating Analog to Digital Signal Converter. Unlike
off-the-shelf A/D Converters used in other instruments, Radian’s A/D Converter
is specifi cally designed and optimized for power and energy measurement. This
unique design makes the RD-20 absolutely unsurpassed in its ability to accurately
measure “real world” waveforms. The RD-20’s A/D Converter is combined with
Radian’s renowned electronically compensated voltage and current input trans-
formers and a hermetically sealed reference set to provide the highest degree of
accuracy, stability and versatility offered in a portable single-phase standard. In the Harmonics Screen the user may select to view voltage or amperage harmonics,
scroll through the harmonic order to observe the phase and magnitude of a specifi c
MEASUREMENTS: The RD-20 is a four quadrant single-phase, simultane- harmonic, and view the total harmonic distortion.
ous measuring instrument that registers both forward and reverse energy fl ow
and provides voltage, current, power and energy (Active, Reactive, Apparent)
information. The Harmonic Analysis option makes available the analysis of
customer load though the 50th harmonic order while the Built-in Comparator
option provides for the automatic calculation of test results for the meters and
standards being tested.
METER AND STANDARD TESTING: The compact light weight design The Setup Screen allows the user to custom confi gure their RD-20. The options
of the RD-20 makes it an ideal reference standard for fi eld testing applications. available are changing the operation of the BNC ports, enabling or disabling the
The RD-20 may be used with a controlled current source to accurately test rev- backlit display, selecting RMS or AVG measurement response, disabling or enabling
enue meters. In fi eld applications the RD-20 can perform a single-phase meter the RD-20’s audible beeps, auto-scrolling the screens, and returning the RD-20 to
accuracy test using existing service load. Pickups to sense meter disk rotation or its original factory default settings.
calibration pulses of infrared, visible light, or KYZ signal plug directly into the
RD-20. The RD-20 may be utilized to test reference standards of lesser accuracy The above features and functions may also be utilized via a PC running Radian
and is also an ideal standard to be intergraded within a meter test bench where Software packages. RR-Confi gure/Analyze allows for the custom confi guration
lesser accuracy is acceptable.
of the RD-20 along with data analysis and RR-Kit software is a set of commands,
routines, and instructions for custom application development.Technical Specifi cations
OPERATING RANGE RD-20 Menu for Measurements & Functionality: The last three digits determine the model.
Current (Autoranging) The fi rst of the last three digits determines the measurement functions; the second of the
.02 to 67 amps per input (three input option) last three digits determines if the unit has a comparator, harmonics analysis, and/or analog
.02 to 75 amps per input (three input extended range option) sense capability; the third of the last three digits determines the current input confi guration.
.02 to 120 amps per input (one input option)
Input voltage: 30 to 600 volts (Autoranging) Specifying the fi rst of the last three digits: RD-20-Xxx
Auxiliary power input: 60 to 600 volts (Autoranging)
Frequency: 45 to 65 Hz MODEL MEASUREMENT FUNCTIONS
Phase Angle: 0 to 360° or -180 to 180°
Power Factor: -1 to 1 RD-20-1xx Whrs, Volts, Amps, VARhrs
Temperature: –20° to +70°C (-4° to +158°F)
Humidity: 0% to 95% non-condensing RD-20-2xx Whrs, Volts, Amps, VARhrs, VAhrs, Qhrs, Watts, VARs,
VA, Phase Angle, Power Factor, Frequency
Shock and vibration: Any that is not destructive
RD-20-3xx Whrs, VARhrs, VAhrs, Qhrs, Volts, Amps, Watts, VARs, VA,
PHYSICAL DESCRIPTION
Vhr, Ahr, V2hr, A2hr, Phase Angle, Power Factor, Frequency
Weight: 2.5 kg (5.5 lbs); 3.6 kg (8lbs) shipping weight
Min & Max measurements: All indicating functions
Size 190.5 mm (7.5") H x 139.7 mm (5.5") D excluding strap
Backlit LCD, 4 line by 16 character
RD-20-4xx Whrs, Volts, Amps, VARhrs, Qhrs, Vahrs, Watts, VARs, VA,
Current inputs: 6mm jacks
Vhr, Ahr, V2hr, A2hr, Phase Angle, PF, Frequency
Potential and Aux power inputs: 4mm Banana type jacks
Min & Max: All indicating functions
BNC connector (port 1) used for input/gating
AVG response: VAhrs, VA, Volts, Vhrs, Amps, Ahrs
BNC connector (port 2) used for pulse outputs
BNC connector (port 3) used for three phase SYNC or analog sense
Specifying the second of the last three digits: RD-20-xXx
5 membrane button keypad: UP/DOWN/ESC-RESET/ENTER/MODE
8 pin RJ-45 jack for RS-232 communication
-x0x No comparator, No harmonic analysis
Pickup input for direct interface to RR-DS, RR-1H, or RR-KYZ
-x1x Built-in comparator
Clamp-on CT input for optional clamp-on current transformer
-x2x Harmonic analysis (RR-Analyze Software included)
-x3x Built-in comparator AND harmonic analysis
TEST AND CALIBRATION
No physical adjustments, all calibration performed with software
AIGC
您好!RD-2X系列产品是我们公司专为满足特定电气应用需求设计的一款高端产品系列。它主要包括两种型号(2X)的电气设备或组件,可能是电动机、变频器、断路器、接触器、电缆或其他相关电力自动化元件。此系列通常具备高效能、高可靠性、节能环保以及智能化控制的特点,旨在提升工业生产过程中的稳定性和效率,同时提供用户友好的操作界面和远程监控功能。如果您需要详细了解具体某一款RD-2X产品的特性和参数,请告知其详细型号以便我们为您提供准确的信息。