Schneider High Power Busway-ILINE II Catalogue 2008
声明:您必须遵守我们的协议,如果您下载了该资源行为将被视为对《电天下账号管理规范》全部内容的认可,本网站资源来自原创,仅供用于学习和交流,请勿用于商业用途。如有侵权、不妥之处,请举报本资源,我们将及时审核处理!
Schneider High Power Busway-ILINE II Catalogue 2008
文本预览
Schneider Busway (Guangzhou) Limited
Postal address As standards, specifications and designs change from time to time, please ask for confirmation
85 Jun Ye Lu, Northern Part of Eastern Section of the information given in this document.
of Guangzhou Economic & Technological
Development District, Guangzhou Printed on recycled paper
510530, PR China
Tel: (86) 20 2820 2828
Fax: (86) 20 2820 2825
2008Schneider busway
from 800 to 6000 A
I-LINE® II
Catalogue 2008Contents
Introduction 3
In decentralised distribution, Schneider busway hits the high note! 3
With Schneider busway, you play all the right notes! 4
Schneider busway, in total harmony with the environment! 6
Schneider busway, fortissimo throughout the range! 8
Schneider busway, a display of advantages! 10
Schneider busway, every one to their music! 12
Schneider busway, hits the right notes! 16
With the Schneider busway tools and services, let us compose your project! 17
Presentation and description 19
Panorama of Schneider busway range 20
General 26
Straight lengths 28
Fittings 29
Supports and fixings 31
Special fittings 32
Plug-in units 33
Catalogue numbers and dimensions 35
Catalogue number coding 36
I-LINE II Copper Busway (CFC)
Straight lengths 38
Straight length components 39
Elbows 41
Flanged ends 51
Cable Tap Box 54
Supports and fixings 55
I-LINE II Copper Contact Busway (BFC)
Straight lengths 58
Straight length components 59
Elbows 61
Flanged ends 66
Cable Tap Box 69
Supports and fixings 70
Plug-in units 72
Design guide 81
Characteristics 82
Designing with I-LINE II busbar trunking system 84
Harmonic currents 88
Fire resistance 90
Measurements and metering 92
Direct current 94
Installation guide 95
Layout advice 96
Horizontal distribution 99
Rising mains 100
Reception, handling and storage 102
Testing and Commissioning 104
Maintenance 108
Schneider Electric 12 Schneider ElectricSchneider Electric 3
noitcudortnI
In decentralised distribution,
Schneider busway hits the high note!
Schneider busway on its second world tour
■ More than 50 years of experience, with hundreds of thousands of installations in
operation throughout the world.
■ Full KEMA type test certification (IEC60439) for each and every ampere rating
of busway.
A total coordination with the
Schneider Electric system
Busway is a part of a comprehensive offering of Schneider Electric products
designed to operate together. This concept covers all low and medium
voltage electrical distribution components. The result is an optimised electrical
installation with even higher performance through full electrical, mechanical and
communication compatibility.
With the new range, you get a complete, tested distribution solution that
complies with standards. It is perfectly suited to traditional applications (factories,
warehouses, etc.) and to the distribution of electrical power from the incoming
transformer on through to all types of loads in offices, commercial premises,
More than 50,000 km of Schneider busbar trunking has been
laboratories, etc.
sold around the world.
Schneider Busway Factories
Dijon Factory was set up in 1972, manufacturing Canalis Busbar trunking system,
ISO 9001 and ISO 14001 certified.
Canlis Factory, Dijon, France
I-LINE busbar trunking system was first introduced by Square D in 1961 in its
production facility in Oxford, Ohio U.S.A. As one of the major brands of the
Schneider Electric, Square D has acquired worldwide recognition in a variety of
busway applications.
Square D facility in Oxford, Ohio U.S.A. is an ISO 9001 and
ISO 14001 registered busbar trunking manufacturing facility.
Schneider Busway Guangzhou was initially set up by Square D, USA in 1997, and
now is a professional busbar trunking manufacturer, product including I-LINE II and
Canalis series, mainly supplying to the Asia Pacific and Middle East market.
Schneider Buway (Guangzhou) Ltd. is certified having ISO
9001 quality management system, ISO 14001 environment
management system and OHSAS 18001 occupational health
and safety management system.4 Schneider Electric
Postal address As standards, specifications and designs change from time to time, please ask for confirmation
85 Jun Ye Lu, Northern Part of Eastern Section of the information given in this document.
of Guangzhou Economic & Technological
Development District, Guangzhou Printed on recycled paper
510530, PR China
Tel: (86) 20 2820 2828
Fax: (86) 20 2820 2825
2008Schneider busway
from 800 to 6000 A
I-LINE® II
Catalogue 2008Contents
Introduction 3
In decentralised distribution, Schneider busway hits the high note! 3
With Schneider busway, you play all the right notes! 4
Schneider busway, in total harmony with the environment! 6
Schneider busway, fortissimo throughout the range! 8
Schneider busway, a display of advantages! 10
Schneider busway, every one to their music! 12
Schneider busway, hits the right notes! 16
With the Schneider busway tools and services, let us compose your project! 17
Presentation and description 19
Panorama of Schneider busway range 20
General 26
Straight lengths 28
Fittings 29
Supports and fixings 31
Special fittings 32
Plug-in units 33
Catalogue numbers and dimensions 35
Catalogue number coding 36
I-LINE II Copper Busway (CFC)
Straight lengths 38
Straight length components 39
Elbows 41
Flanged ends 51
Cable Tap Box 54
Supports and fixings 55
I-LINE II Copper Contact Busway (BFC)
Straight lengths 58
Straight length components 59
Elbows 61
Flanged ends 66
Cable Tap Box 69
Supports and fixings 70
Plug-in units 72
Design guide 81
Characteristics 82
Designing with I-LINE II busbar trunking system 84
Harmonic currents 88
Fire resistance 90
Measurements and metering 92
Direct current 94
Installation guide 95
Layout advice 96
Horizontal distribution 99
Rising mains 100
Reception, handling and storage 102
Testing and Commissioning 104
Maintenance 108
Schneider Electric 12 Schneider ElectricSchneider Electric 3
noitcudortnI
In decentralised distribution,
Schneider busway hits the high note!
Schneider busway on its second world tour
■ More than 50 years of experience, with hundreds of thousands of installations in
operation throughout the world.
■ Full KEMA type test certification (IEC60439) for each and every ampere rating
of busway.
A total coordination with the
Schneider Electric system
Busway is a part of a comprehensive offering of Schneider Electric products
designed to operate together. This concept covers all low and medium
voltage electrical distribution components. The result is an optimised electrical
installation with even higher performance through full electrical, mechanical and
communication compatibility.
With the new range, you get a complete, tested distribution solution that
complies with standards. It is perfectly suited to traditional applications (factories,
warehouses, etc.) and to the distribution of electrical power from the incoming
transformer on through to all types of loads in offices, commercial premises,
More than 50,000 km of Schneider busbar trunking has been
laboratories, etc.
sold around the world.
Schneider Busway Factories
Dijon Factory was set up in 1972, manufacturing Canalis Busbar trunking system,
ISO 9001 and ISO 14001 certified.
Canlis Factory, Dijon, France
I-LINE busbar trunking system was first introduced by Square D in 1961 in its
production facility in Oxford, Ohio U.S.A. As one of the major brands of the
Schneider Electric, Square D has acquired worldwide recognition in a variety of
busway applications.
Square D facility in Oxford, Ohio U.S.A. is an ISO 9001 and
ISO 14001 registered busbar trunking manufacturing facility.
Schneider Busway Guangzhou was initially set up by Square D, USA in 1997, and
now is a professional busbar trunking manufacturer, product including I-LINE II and
Canalis series, mainly supplying to the Asia Pacific and Middle East market.
Schneider Buway (Guangzhou) Ltd. is certified having ISO
9001 quality management system, ISO 14001 environment
management system and OHSAS 18001 occupational health
and safety management system.4 Schneider Electric
AIGC
当然可以。"Schneider High Power Busway-ILINE II Catalogue 2008" 是一款由施耐德电气(Schneider Electric)公司在2008年发布的产品目录,专门针对其高性能高压母线桥(High Power Busway)系统 - ILINE II 系列。该catalogue详细介绍了ILINE II 母线桥系统的各种配置、技术规格、安装方法、电气性能参数、安全特性以及应用案例等内容。作为一款高功率密度、模块化设计、易于安装和维护的电力分配解决方案,ILINE II 可以为工业、商业和楼宇自动化项目提供可靠的中压电力传输服务,适用于广泛的功率需求范围,从几百千瓦到数兆瓦不等。这份2008年的catalogue反映了当时施耐德电气在高压母线桥技术领域的先进水平及其对市场需求的响应。